Light intensity of the light-curing units in private clinics in the city of Cuenca, Ecuador

Introduction: Light intensity emitted by the curing lamps represents an essential factor in the activation of photosensitive materials. The adequate supply of intensity, as well as the correct functioning of the device, it ensures a correct dental treatment. Objective: To know the light intensity, t...

Full description

Bibliographic Details
Main Authors: Ajila Bohórquez, Ana Mischell, Lalangui Matamoros, Joe Javier
Other Authors: Palacios Astudillo, Iván Andrés
Format: Article
Language:spa
Published: Universidad de Cuenca 2022
Subjects:
Online Access:http://dspace.ucuenca.edu.ec/handle/123456789/38810
_version_ 1785802376293122048
author Ajila Bohórquez, Ana Mischell
Lalangui Matamoros, Joe Javier
author2 Palacios Astudillo, Iván Andrés
author_facet Palacios Astudillo, Iván Andrés
Ajila Bohórquez, Ana Mischell
Lalangui Matamoros, Joe Javier
author_sort Ajila Bohórquez, Ana Mischell
collection DSpace
description Introduction: Light intensity emitted by the curing lamps represents an essential factor in the activation of photosensitive materials. The adequate supply of intensity, as well as the correct functioning of the device, it ensures a correct dental treatment. Objective: To know the light intensity, type, and fiber state of the curing lamps used in private dental offices in the city of Cuenca - Ecuador. Materials and methods: The cross-sectional descriptive study assessed the light intensity of 366 light-curing lamps from private clinics with the use of a Bluephase Meter II radiometer, besides the Likert-scale based evaluation of its type and condition. Data analysis was done with the software R v.3.2 and its interface R-Studio v.1.2. Results: Inadequate light intensities were observed in 18% of the total analyzed units. Inadequate light intensities corresponded at 46% of Halogen lamps, and 12% of LED units. Likewise, 17% of units presented fiber fracture, while 52% showed residues of biomaterials on it. The predominant diameter in the units was 8mm, representing 65% of the total of light-curing lamps analyzed. Conclusions: LED lamps presented adequate light intensities in higher proportion in comparison to halogen lamps. It was shown that the presence of fractures and residues decrease the intensity of the photocuring units. Furthermore, we indicate that a periodic control of the lightcuring units is necessary to prevent future problems in oral treatments.
format Article
id oai:dspace.ucuenca.edu.ec:123456789-38810
institution Universidad de Cuenca
language spa
publishDate 2022
publisher Universidad de Cuenca
record_format dspace
spelling oai:dspace.ucuenca.edu.ec:123456789-388102022-04-25T09:00:25Z Light intensity of the light-curing units in private clinics in the city of Cuenca, Ecuador Ajila Bohórquez, Ana Mischell Lalangui Matamoros, Joe Javier Palacios Astudillo, Iván Andrés Odontología Fotopolimerización Fibra óptica Radiómetro dental Fotometría Introduction: Light intensity emitted by the curing lamps represents an essential factor in the activation of photosensitive materials. The adequate supply of intensity, as well as the correct functioning of the device, it ensures a correct dental treatment. Objective: To know the light intensity, type, and fiber state of the curing lamps used in private dental offices in the city of Cuenca - Ecuador. Materials and methods: The cross-sectional descriptive study assessed the light intensity of 366 light-curing lamps from private clinics with the use of a Bluephase Meter II radiometer, besides the Likert-scale based evaluation of its type and condition. Data analysis was done with the software R v.3.2 and its interface R-Studio v.1.2. Results: Inadequate light intensities were observed in 18% of the total analyzed units. Inadequate light intensities corresponded at 46% of Halogen lamps, and 12% of LED units. Likewise, 17% of units presented fiber fracture, while 52% showed residues of biomaterials on it. The predominant diameter in the units was 8mm, representing 65% of the total of light-curing lamps analyzed. Conclusions: LED lamps presented adequate light intensities in higher proportion in comparison to halogen lamps. It was shown that the presence of fractures and residues decrease the intensity of the photocuring units. Furthermore, we indicate that a periodic control of the lightcuring units is necessary to prevent future problems in oral treatments. Odontólogo Cuenca 2022-04-19T19:23:56Z 2022-04-19T19:23:56Z 2021-01-20 Article http://dspace.ucuenca.edu.ec/handle/123456789/38810 spa ODON;656 Attribution-NonCommercial-NoDerivatives 4.0 Internacional http://creativecommons.org/licenses/by-nc-nd/4.0/ openAccess application/pdf 17 páginas application/pdf Universidad de Cuenca
spellingShingle Odontología
Fotopolimerización
Fibra óptica
Radiómetro dental
Fotometría
Ajila Bohórquez, Ana Mischell
Lalangui Matamoros, Joe Javier
Light intensity of the light-curing units in private clinics in the city of Cuenca, Ecuador
title Light intensity of the light-curing units in private clinics in the city of Cuenca, Ecuador
title_full Light intensity of the light-curing units in private clinics in the city of Cuenca, Ecuador
title_fullStr Light intensity of the light-curing units in private clinics in the city of Cuenca, Ecuador
title_full_unstemmed Light intensity of the light-curing units in private clinics in the city of Cuenca, Ecuador
title_short Light intensity of the light-curing units in private clinics in the city of Cuenca, Ecuador
title_sort light intensity of the light-curing units in private clinics in the city of cuenca, ecuador
topic Odontología
Fotopolimerización
Fibra óptica
Radiómetro dental
Fotometría
url http://dspace.ucuenca.edu.ec/handle/123456789/38810
work_keys_str_mv AT ajilabohorquezanamischell lightintensityofthelightcuringunitsinprivateclinicsinthecityofcuencaecuador
AT lalanguimatamorosjoejavier lightintensityofthelightcuringunitsinprivateclinicsinthecityofcuencaecuador