Light intensity of the light-curing units in private clinics in the city of Cuenca, Ecuador
Introduction: Light intensity emitted by the curing lamps represents an essential factor in the activation of photosensitive materials. The adequate supply of intensity, as well as the correct functioning of the device, it ensures a correct dental treatment. Objective: To know the light intensity, t...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Article |
Language: | spa |
Published: |
Universidad de Cuenca
2022
|
Subjects: | |
Online Access: | http://dspace.ucuenca.edu.ec/handle/123456789/38810 |
_version_ | 1785802376293122048 |
---|---|
author | Ajila Bohórquez, Ana Mischell Lalangui Matamoros, Joe Javier |
author2 | Palacios Astudillo, Iván Andrés |
author_facet | Palacios Astudillo, Iván Andrés Ajila Bohórquez, Ana Mischell Lalangui Matamoros, Joe Javier |
author_sort | Ajila Bohórquez, Ana Mischell |
collection | DSpace |
description | Introduction: Light intensity emitted by the curing lamps represents an essential factor in the activation of photosensitive materials. The adequate supply of intensity, as well as the correct functioning of the device, it ensures a correct dental treatment. Objective: To know the light intensity, type, and fiber state of the curing
lamps used in private dental offices in the city of Cuenca - Ecuador. Materials and methods: The cross-sectional descriptive study assessed the light intensity of 366 light-curing lamps from private clinics with the use of a Bluephase Meter II radiometer, besides the Likert-scale based evaluation of its type and condition.
Data analysis was done with the software R v.3.2 and its interface R-Studio v.1.2.
Results: Inadequate light intensities were observed in 18% of the total analyzed units. Inadequate light intensities corresponded at 46% of Halogen lamps, and 12% of LED units. Likewise, 17% of units presented fiber fracture, while 52% showed residues of biomaterials on it. The predominant diameter in the units was
8mm, representing 65% of the total of light-curing lamps analyzed.
Conclusions: LED lamps presented adequate light intensities in higher proportion in comparison to halogen lamps. It was shown that the presence of fractures and residues decrease the intensity of the photocuring units. Furthermore, we indicate that a periodic control of the lightcuring units is necessary to prevent future problems in
oral treatments. |
format | Article |
id | oai:dspace.ucuenca.edu.ec:123456789-38810 |
institution | Universidad de Cuenca |
language | spa |
publishDate | 2022 |
publisher | Universidad de Cuenca |
record_format | dspace |
spelling | oai:dspace.ucuenca.edu.ec:123456789-388102022-04-25T09:00:25Z Light intensity of the light-curing units in private clinics in the city of Cuenca, Ecuador Ajila Bohórquez, Ana Mischell Lalangui Matamoros, Joe Javier Palacios Astudillo, Iván Andrés Odontología Fotopolimerización Fibra óptica Radiómetro dental Fotometría Introduction: Light intensity emitted by the curing lamps represents an essential factor in the activation of photosensitive materials. The adequate supply of intensity, as well as the correct functioning of the device, it ensures a correct dental treatment. Objective: To know the light intensity, type, and fiber state of the curing lamps used in private dental offices in the city of Cuenca - Ecuador. Materials and methods: The cross-sectional descriptive study assessed the light intensity of 366 light-curing lamps from private clinics with the use of a Bluephase Meter II radiometer, besides the Likert-scale based evaluation of its type and condition. Data analysis was done with the software R v.3.2 and its interface R-Studio v.1.2. Results: Inadequate light intensities were observed in 18% of the total analyzed units. Inadequate light intensities corresponded at 46% of Halogen lamps, and 12% of LED units. Likewise, 17% of units presented fiber fracture, while 52% showed residues of biomaterials on it. The predominant diameter in the units was 8mm, representing 65% of the total of light-curing lamps analyzed. Conclusions: LED lamps presented adequate light intensities in higher proportion in comparison to halogen lamps. It was shown that the presence of fractures and residues decrease the intensity of the photocuring units. Furthermore, we indicate that a periodic control of the lightcuring units is necessary to prevent future problems in oral treatments. Odontólogo Cuenca 2022-04-19T19:23:56Z 2022-04-19T19:23:56Z 2021-01-20 Article http://dspace.ucuenca.edu.ec/handle/123456789/38810 spa ODON;656 Attribution-NonCommercial-NoDerivatives 4.0 Internacional http://creativecommons.org/licenses/by-nc-nd/4.0/ openAccess application/pdf 17 páginas application/pdf Universidad de Cuenca |
spellingShingle | Odontología Fotopolimerización Fibra óptica Radiómetro dental Fotometría Ajila Bohórquez, Ana Mischell Lalangui Matamoros, Joe Javier Light intensity of the light-curing units in private clinics in the city of Cuenca, Ecuador |
title | Light intensity of the light-curing units in private clinics in the city of Cuenca, Ecuador |
title_full | Light intensity of the light-curing units in private clinics in the city of Cuenca, Ecuador |
title_fullStr | Light intensity of the light-curing units in private clinics in the city of Cuenca, Ecuador |
title_full_unstemmed | Light intensity of the light-curing units in private clinics in the city of Cuenca, Ecuador |
title_short | Light intensity of the light-curing units in private clinics in the city of Cuenca, Ecuador |
title_sort | light intensity of the light-curing units in private clinics in the city of cuenca, ecuador |
topic | Odontología Fotopolimerización Fibra óptica Radiómetro dental Fotometría |
url | http://dspace.ucuenca.edu.ec/handle/123456789/38810 |
work_keys_str_mv | AT ajilabohorquezanamischell lightintensityofthelightcuringunitsinprivateclinicsinthecityofcuencaecuador AT lalanguimatamorosjoejavier lightintensityofthelightcuringunitsinprivateclinicsinthecityofcuencaecuador |