Factores de riesgo asociados a la permanencia de accesos vasculares venosos en los recién nacidos ingresados en el servicio de neonatología del Hospital Vicente Corral Moscoso, Cuenca 2013

Objetivo: la presente investigación trata de identificar los factores de riesgo asociados a la permanencia de accesos vasculares venosos en los recién nacidos ingresados en el servicio de Neonatología de la ciudad de Cuenca. Material y Métodos: es un estudio de prevalencia, permitió determinar l...

Full description

Bibliographic Details
Main Author: González Castillo, Angela Marcela
Other Authors: Verdugo Sánchez, Adriana Elizabeth
Format: bachelorThesis
Language:spa
Published: 2013
Subjects:
Online Access:http://dspace.ucuenca.edu.ec/handle/123456789/4862
_version_ 1785802397792075776
author González Castillo, Angela Marcela
author2 Verdugo Sánchez, Adriana Elizabeth
author_facet Verdugo Sánchez, Adriana Elizabeth
González Castillo, Angela Marcela
author_sort González Castillo, Angela Marcela
collection DSpace
description Objetivo: la presente investigación trata de identificar los factores de riesgo asociados a la permanencia de accesos vasculares venosos en los recién nacidos ingresados en el servicio de Neonatología de la ciudad de Cuenca. Material y Métodos: es un estudio de prevalencia, permitió determinar las actitudes para la colocación y remoción de los accesos vasculares venosos según función, lugar de colocación y tipo de acceso utilizado en el área. El muestreo se realizó por selección e incluyó a 79 neonatos a quienes se les colocó accesos vasculares venosos en los meses de marzo, abril y mayo del año 2013. Técnicas e instrumentos: como técnica se utilizó la entrevista y la observación directa e indirecta y como instrumento un formulario previamente elaborado y aplicado por la autora; para el análisis de los datos y presentación de resultados se utilizó los programas informáticos SPSS versión 21, Excel, Word, se presentó en tablas de 2x2. Resultados: el 81% de neonatos ingresó antes de las 24h de vida, el 41% son prematuros, el 47% tienen bajo peso al nacer, entre las principales complicaciones tenemos el 30% flebitis y el 30% extravasación. Los motivos de remoción del acceso venoso corresponde: el 26% termino del tratamiento, 17% edema del sitio de inserción y difícil acceso venosos 16%. Conclusión: el personal de enfermería debe enfatizar su cuidado y vigilancia suficientemente requerida antes, durante y después de haber colocado un acceso venoso, para prevenir complicaciones. PALABRAS CLAVES: PREMATURO, ACCESO VASCULAR VENOSO, COMPLICACIONES, MOTIVOS DE REMOCIÓN, ASEPSIA Y ANTISEPSIA DE LOS PROCEDIMIENTOS.
format bachelorThesis
id oai:dspace.ucuenca.edu.ec:123456789-4862
institution Universidad de Cuenca
language spa
publishDate 2013
record_format dspace
spelling oai:dspace.ucuenca.edu.ec:123456789-48622020-08-04T20:23:07Z Factores de riesgo asociados a la permanencia de accesos vasculares venosos en los recién nacidos ingresados en el servicio de neonatología del Hospital Vicente Corral Moscoso, Cuenca 2013 González Castillo, Angela Marcela Verdugo Sánchez, Adriana Elizabeth Montaño Peralta, Bertha Soraya Prematuro Acceso Vascular Venoso Complicaciones Motivos De Remocion Asepsia De Los Procedimientos Antisepsia De Los Procedimientos Hospital Vicente Corral Moscoso Cuenca Ecuador Objetivo: la presente investigación trata de identificar los factores de riesgo asociados a la permanencia de accesos vasculares venosos en los recién nacidos ingresados en el servicio de Neonatología de la ciudad de Cuenca. Material y Métodos: es un estudio de prevalencia, permitió determinar las actitudes para la colocación y remoción de los accesos vasculares venosos según función, lugar de colocación y tipo de acceso utilizado en el área. El muestreo se realizó por selección e incluyó a 79 neonatos a quienes se les colocó accesos vasculares venosos en los meses de marzo, abril y mayo del año 2013. Técnicas e instrumentos: como técnica se utilizó la entrevista y la observación directa e indirecta y como instrumento un formulario previamente elaborado y aplicado por la autora; para el análisis de los datos y presentación de resultados se utilizó los programas informáticos SPSS versión 21, Excel, Word, se presentó en tablas de 2x2. Resultados: el 81% de neonatos ingresó antes de las 24h de vida, el 41% son prematuros, el 47% tienen bajo peso al nacer, entre las principales complicaciones tenemos el 30% flebitis y el 30% extravasación. Los motivos de remoción del acceso venoso corresponde: el 26% termino del tratamiento, 17% edema del sitio de inserción y difícil acceso venosos 16%. Conclusión: el personal de enfermería debe enfatizar su cuidado y vigilancia suficientemente requerida antes, durante y después de haber colocado un acceso venoso, para prevenir complicaciones. PALABRAS CLAVES: PREMATURO, ACCESO VASCULAR VENOSO, COMPLICACIONES, MOTIVOS DE REMOCIÓN, ASEPSIA Y ANTISEPSIA DE LOS PROCEDIMIENTOS. Objective: This research intends to identify the risk factors associated to the permanence of venous vascular accesses in the newly born that have entered the service of Neonatology in the city of Cuenca Material and Methods: It is a descriptive study that allowed us to determine the criteria for the placement and removal of the venous vascular accesses according to their function, place of collocation, and type of access. The universe was constituted by 700 newly born who were registered in neonatology in the year 2012. The sample framework corresponds to 79 newly born who were introduced venous vascular accesses in the months of March, April, and May of the year 2013. The techniques used were the interview and direct and indirect observation, and the instrument utilized was a previously made form which was applied by the author. The computer programs, SPSS, version 21, Excel, and Word were used for the data analysis and the presentation of results. The results are shown in 2 x 2 tables. Results: The risk factors associated to the permanence of the venous vascular accesses are the following. The 81% of newly born entered the area before their 24 hours of life. The 32% of newly born showed retardation in intrauterine growth. One hundred venous vascular accesses were installed, of which, 74% were peripheral, 12% were percutaneous, 5% were central, and 9% umbilical. 63% venous vascular accesses were introduced in premature newly born with low weight (<2500 gr.). The most frequently place of insertion was the cephalic vein of the arm with the 23%. The removal responded to the following; the 26% to the end of treatment and the 17% to edema in the place of insertion. Conclusion: From this research, it is concluded that the nursing personnel do not adequately perform the insertion and maintenance techniques of the venous vascular accesses nor the disinfection or sterilization, especially in the peripheral venous accesses, for which reason, complications were observed. KEYWORDS: PREMATURE, VENOUS VASCULAR ACCESS, OMPLICATIONS, REMOVAL REASONS, DISINFECTION AND STERILIZATION OF PROCEDURES Licenciado en Enfermería Cuenca 2013-12-19T15:30:44Z 2013-12-19T15:30:44Z 2013 bachelorThesis http://dspace.ucuenca.edu.ec/handle/123456789/4862 spa ENF;454 openAccess http://creativecommons.org/licenses/by-nc-sa/3.0/ec/ application/pdf application/pdf
spellingShingle Prematuro
Acceso Vascular Venoso
Complicaciones
Motivos De Remocion
Asepsia De Los Procedimientos
Antisepsia De Los Procedimientos
Hospital Vicente Corral Moscoso
Cuenca
Ecuador
González Castillo, Angela Marcela
Factores de riesgo asociados a la permanencia de accesos vasculares venosos en los recién nacidos ingresados en el servicio de neonatología del Hospital Vicente Corral Moscoso, Cuenca 2013
title Factores de riesgo asociados a la permanencia de accesos vasculares venosos en los recién nacidos ingresados en el servicio de neonatología del Hospital Vicente Corral Moscoso, Cuenca 2013
title_full Factores de riesgo asociados a la permanencia de accesos vasculares venosos en los recién nacidos ingresados en el servicio de neonatología del Hospital Vicente Corral Moscoso, Cuenca 2013
title_fullStr Factores de riesgo asociados a la permanencia de accesos vasculares venosos en los recién nacidos ingresados en el servicio de neonatología del Hospital Vicente Corral Moscoso, Cuenca 2013
title_full_unstemmed Factores de riesgo asociados a la permanencia de accesos vasculares venosos en los recién nacidos ingresados en el servicio de neonatología del Hospital Vicente Corral Moscoso, Cuenca 2013
title_short Factores de riesgo asociados a la permanencia de accesos vasculares venosos en los recién nacidos ingresados en el servicio de neonatología del Hospital Vicente Corral Moscoso, Cuenca 2013
title_sort factores de riesgo asociados a la permanencia de accesos vasculares venosos en los recién nacidos ingresados en el servicio de neonatología del hospital vicente corral moscoso, cuenca 2013
topic Prematuro
Acceso Vascular Venoso
Complicaciones
Motivos De Remocion
Asepsia De Los Procedimientos
Antisepsia De Los Procedimientos
Hospital Vicente Corral Moscoso
Cuenca
Ecuador
url http://dspace.ucuenca.edu.ec/handle/123456789/4862