Application of Semi-Empirical Ventilation Models in A Mediterranean Greenhouse with Opposing Thermal and Wind Effects. Use of Non-Constant Cd (Pressure Drop Coefficient Through the Vents) and Cw (Wind Effect Coefficient)
The present work analyses the natural ventilation of a multi-span greenhouse with one roof vent and two side vents by means of sonic anemometry. Opening the roof vent to windward, one side vent to leeward, and the other side vents to windward (this last vent obstructed by another greenhouse), causes...
Main Authors: | López Martínez, Alejandro, Molina Aiz, Francisco Domingo, Valera Martínez, Diego Luis, López Martínez, Javier, Peña Fernández, Ana Araceli, Espinoza Ramos, Karlos |
---|---|
Format: | info:eu-repo/semantics/article |
Language: | English |
Published: |
MDPI
2020
|
Subjects: | |
Online Access: | http://hdl.handle.net/10835/7391 |
Similar Items
-
Sonic Anemometry to Measure Natural Ventilation in Greenhouses
by: López Martínez, Alejandro, et al.
Published: (2020) -
Analysis of Turbulent Air Flow Characteristics Due to the Presence of a 13 × 30 Threads·cm−2 Insect Proof Screen on the Side Windows of a Mediterranean Greenhouse
by: López Martínez, Alejandro, et al.
Published: (2022) -
Encouraging natural ventilation to improve indoor environmental conditions at schools. Case studies in the north of Spain before and during COVID
by: Monge-Barrio, A. (Aurora), et al.
Published: (2022) -
Thermography and Sonic Anemometry to Analyze Air Heaters in Mediterranean Greenhouses
by: López Martínez, Alejandro, et al.
Published: (2020) -
Encouraging natural ventilation to improve indoor environmental conditions at schools. case studies in the north of Spain before and during COVID
by: Monge-Barrio, A. (Aurora), et al.
Published: (2022)