Validity and Reliability of a New Inertial Device for Monitoring Range of Motion at the Pelvis during Sexual Intercourse

To understand the physical demands of sexual intercourse, it is necessary to monitor the kinematic parameters of this activity using relatively non-invasive technology. The aims of this study are to analyze the validity and reliability of an inertial device for monitoring the range of motion at the...

Full description

Bibliographic Details
Main Authors: Oliva Lozano, Jose María, Martín Fuentes, Isabel, Muyor Rodríguez, José María
Format: info:eu-repo/semantics/article
Language:English
Published: MDPI 2020
Subjects:
Online Access:http://hdl.handle.net/10835/8098
_version_ 1789406734209515520
author Oliva Lozano, Jose María
Martín Fuentes, Isabel
Muyor Rodríguez, José María
author_facet Oliva Lozano, Jose María
Martín Fuentes, Isabel
Muyor Rodríguez, José María
author_sort Oliva Lozano, Jose María
collection DSpace
description To understand the physical demands of sexual intercourse, it is necessary to monitor the kinematic parameters of this activity using relatively non-invasive technology. The aims of this study are to analyze the validity and reliability of an inertial device for monitoring the range of motion at the pelvis during simulated intercourse and compare the range of motion (ROM). Twenty-six adults were monitored during intercourse using an inertial device (WIMU) and a motion capture system (gold standard) in a test that consisted of 4 sets of 20 simulated in–out cycles (IOC) in missionary and cowgirl positions. Men and women were tested separately in a laboratory setting for simulated intercourse aims. There were no differences between the WIMU and the gold standard system at fast pace (p > 0.05), whereas there were differences at slow pace (~2.04°; p ≤ 0.05; d = 0.17). Intraclass correlation coefficients (ICCs) for the relationship between systems was very close to 1 at both paces (slow: 0.981; fast: 0.998). The test–retest reliability analysis did not show any difference between sets of measurements. In conclusion, WIMU could be considered as a valid and reliable device for IOC range of motion monitoring during sexual intercourse in missionary and cowgirl positions.
format info:eu-repo/semantics/article
id oai:repositorio.ual.es:10835-8098
institution Universidad de Cuenca
language English
publishDate 2020
publisher MDPI
record_format dspace
spelling oai:repositorio.ual.es:10835-80982023-04-12T19:15:45Z Validity and Reliability of a New Inertial Device for Monitoring Range of Motion at the Pelvis during Sexual Intercourse Oliva Lozano, Jose María Martín Fuentes, Isabel Muyor Rodríguez, José María sexual activity posture IOC kinematics WIMU To understand the physical demands of sexual intercourse, it is necessary to monitor the kinematic parameters of this activity using relatively non-invasive technology. The aims of this study are to analyze the validity and reliability of an inertial device for monitoring the range of motion at the pelvis during simulated intercourse and compare the range of motion (ROM). Twenty-six adults were monitored during intercourse using an inertial device (WIMU) and a motion capture system (gold standard) in a test that consisted of 4 sets of 20 simulated in–out cycles (IOC) in missionary and cowgirl positions. Men and women were tested separately in a laboratory setting for simulated intercourse aims. There were no differences between the WIMU and the gold standard system at fast pace (p > 0.05), whereas there were differences at slow pace (~2.04°; p ≤ 0.05; d = 0.17). Intraclass correlation coefficients (ICCs) for the relationship between systems was very close to 1 at both paces (slow: 0.981; fast: 0.998). The test–retest reliability analysis did not show any difference between sets of measurements. In conclusion, WIMU could be considered as a valid and reliable device for IOC range of motion monitoring during sexual intercourse in missionary and cowgirl positions. 2020-04-28T07:29:22Z 2020-04-28T07:29:22Z 2020-04-22 info:eu-repo/semantics/article 1660-4601 http://hdl.handle.net/10835/8098 en https://www.mdpi.com/1660-4601/17/8/2884 Attribution-NonCommercial-NoDerivatives 4.0 Internacional http://creativecommons.org/licenses/by-nc-nd/4.0/ info:eu-repo/semantics/openAccess MDPI
spellingShingle sexual activity
posture
IOC
kinematics
WIMU
Oliva Lozano, Jose María
Martín Fuentes, Isabel
Muyor Rodríguez, José María
Validity and Reliability of a New Inertial Device for Monitoring Range of Motion at the Pelvis during Sexual Intercourse
title Validity and Reliability of a New Inertial Device for Monitoring Range of Motion at the Pelvis during Sexual Intercourse
title_full Validity and Reliability of a New Inertial Device for Monitoring Range of Motion at the Pelvis during Sexual Intercourse
title_fullStr Validity and Reliability of a New Inertial Device for Monitoring Range of Motion at the Pelvis during Sexual Intercourse
title_full_unstemmed Validity and Reliability of a New Inertial Device for Monitoring Range of Motion at the Pelvis during Sexual Intercourse
title_short Validity and Reliability of a New Inertial Device for Monitoring Range of Motion at the Pelvis during Sexual Intercourse
title_sort validity and reliability of a new inertial device for monitoring range of motion at the pelvis during sexual intercourse
topic sexual activity
posture
IOC
kinematics
WIMU
url http://hdl.handle.net/10835/8098
work_keys_str_mv AT olivalozanojosemaria validityandreliabilityofanewinertialdeviceformonitoringrangeofmotionatthepelvisduringsexualintercourse
AT martinfuentesisabel validityandreliabilityofanewinertialdeviceformonitoringrangeofmotionatthepelvisduringsexualintercourse
AT muyorrodriguezjosemaria validityandreliabilityofanewinertialdeviceformonitoringrangeofmotionatthepelvisduringsexualintercourse